DLI Calculator

Calculate daily light integral from PPFD and photoperiod, and the PPFD or hours needed to hit a target DLI.

Loading calculator…

What this tool does

The DLI Calculator multiplies canopy PPFD by the photoperiod (× 0.0036) to give the total photosynthetic light a plant receives per day in mol/m²/day, and works backwards from a target DLI to the PPFD or hours required.

How to use the DLI Calculator

  1. Measure or look up PPFD at canopy level (a PAR meter or your light's published PPFD map).
  2. Enter the hours the lights are on.
  3. Enter a target DLI for your crop to see what it would take to reach it.

Formula

DLI = PPFD × hours × 0.0036
0.0036
3,600 seconds per hour ÷ 1,000,000 µmol per mol
PPFD
Photosynthetic photon flux density, µmol/m²/s, 400–700 nm

Worked example

800 µmol/m²/s for 18 hours delivers 800 × 18 × 0.0036 = 51.8 mol/m²/day — above the 30 target.

Inputs

  • PPFD at canopy (µmol/m²/s)800
  • Photoperiod (hours of light)18
  • Target DLI (mol/m²/day)30

Result

  • Daily light integral51.84 mol/m²/day
  • PPFD needed for target DLI463 µmol/m²/s
  • Hours needed at this PPFD10.4 hours

Typical DLI targets (mol/m²/day)

Crop / stageDLI
Seedlings / clones6–12
Leafy greens & herbs12–18
Vegetative growth (fruiting crops)20–30
Flowering fruiting crops30–50+
Full-sun outdoor summer day50–65

Results explained

DLI
Total daily photosynthetic light at the canopy.
PPFD needed
Intensity that would exactly hit the target in your photoperiod.
Hours needed
Photoperiod that would hit the target at your current PPFD.

Frequently asked questions

DLI = PPFD × hours of light × 0.0036. At 600 µmol/m²/s for 16 hours: 600 × 16 × 0.0036 = 34.6 mol/m²/day.

Seedlings thrive at 6–12, leafy greens at 12–18, and fruiting/flowering crops at 30–50 mol/m²/day. More light past a crop's saturation mostly buys heat and electricity bills.

Yes — DLI only counts the daily total, which is why the tool shows the hours needed at your PPFD. Limits: most plants need a dark period, and very low intensity for very long hours underperforms the same DLI delivered brighter.

Lux is weighted for human eyes (green-heavy); plants use 400–700 nm photons roughly evenly. A lux reading can't convert to PPFD reliably without knowing the light spectrum — use the manufacturer's PPFD map or a PAR meter.

They are the two dials of indoor growing: DLI sets how much the plant is asked to work, VPD sets how easily it can transpire while doing it. The VPD Calculator is the companion tool.