Manual J Load Calculator

Estimate residential heating loss and sensible cooling gain from building surfaces and air infiltration.

Loading calculator…

What this tool does

Estimate residential heating loss and sensible cooling gain from building surfaces and air infiltration. Simplified estimator, NOT a certified ACCA Manual J calculation. Climate is descriptive; enter local design temperatures explicitly.

How to use the Manual J Load Calculator

  1. Enter or select floor area in sqft.
  2. Enter or select ceiling height in ft.
  3. Enter or select net exterior wall area in sqft.
  4. Enter or select wall r-value.
  5. Enter or select ceiling r-value.
  6. Enter or select window area in sqft.
  7. Enter or select window u-factor.
  8. Enter or select door area in sqft.
  9. Enter or select door r-value.
  10. Enter or select climate zone (editable design δt below).
  11. Enter or select heating indoor-outdoor difference (°f).
  12. Enter or select cooling outdoor-indoor difference (°f).
  13. Enter or select infiltration ach.
  14. Enter or select occupants.
  15. Enter or select appliance heat gain (btu/h).
  16. Enter or select window solar gain (btu/h per sq ft).
  17. Read the calculated result; change any measurement to compare alternatives.

Formula

UA=wallArea/wallR+area/roofR+windows×windowU+doors/doorR; infiltrationCFM=area×height×ACH/60; heating=(UA+1.08×CFM)×heatingΔT; cooling=(UA+1.08×CFM)×coolingΔT+windows×solar+people×400+appliances
area
Floor area (sqft, before metric conversion)
height
Ceiling height (ft, before metric conversion)
wallArea
Net exterior wall area (sqft, before metric conversion)
wallR
Wall R-value
roofR
Ceiling R-value
windows
Window area (sqft, before metric conversion)
windowU
Window U-factor
doors
Door area (sqft, before metric conversion)
doorR
Door R-value
climate
Climate zone (editable design ΔT below)
heatingDT
Heating indoor-outdoor difference (°F)
coolingDT
Cooling outdoor-indoor difference (°F)
ach
Infiltration ACH
people
Occupants
appliances
Appliance heat gain (BTU/h)
solar
Window solar gain (BTU/h per sq ft)

Simplified estimator, NOT a certified ACCA Manual J calculation. Climate is descriptive; enter local design temperatures explicitly.

Worked example

For manual j load calculator, the following measurements illustrate the exact method: Floor area: 1500; Ceiling height: 8; Net exterior wall area: 1200; Wall R-value: 13; Ceiling R-value: 30; Window area: 200; Window U-factor: 0.35; Door area: 40; Door R-value: 5; Climate zone (editable design ΔT below): mixed; Heating indoor-outdoor difference (°F): 60; Cooling outdoor-indoor difference (°F): 20; Infiltration ACH: 0.5; Occupants: 4; Appliance heat gain (BTU/h): 2000; Window solar gain (BTU/h per sq ft): 50.

Inputs

  • Floor area1500 sq ft
  • Ceiling height8 ft
  • Net exterior wall area1200 sq ft
  • Wall R-value13
  • Ceiling R-value30
  • Window area200 sq ft
  • Window U-factor0.35
  • Door area40 sq ft
  • Door R-value5
  • Climate zone (editable design ΔT below)Mixed
  • Heating indoor-outdoor difference (°F)60
  • Cooling outdoor-indoor difference (°F)20
  • Infiltration ACH0.5
  • Occupants4
  • Appliance heat gain (BTU/h)2000
  • Window solar gain (BTU/h per sq ft)50

Result

  • Estimated heating loss (BTU/h)19,698.46
  • Estimated cooling gain (BTU/h)20,166.15

Results explained

Estimated heating loss (BTU/h)
Estimated heating loss (BTU/h) from the formula above. Simplified estimator, NOT a certified ACCA Manual J calculation. Climate is descriptive; enter local design temperatures explicitly.
Estimated cooling gain (BTU/h)
Estimated cooling gain (BTU/h) from the formula above. Simplified estimator, NOT a certified ACCA Manual J calculation. Climate is descriptive; enter local design temperatures explicitly.

Frequently asked questions

UA=wallArea/wallR+area/roofR+windows×windowU+doors/doorR; infiltrationCFM=area×height×ACH/60; heating=(UA+1.08×CFM)×heatingΔT; cooling=(UA+1.08×CFM)×coolingΔT+windows×solar+people×400+appliances

Simplified estimator, NOT a certified ACCA Manual J calculation. Climate is descriptive; enter local design temperatures explicitly.

No. Electrical and HVAC results are estimates. Installation must comply with local codes and be checked by a qualified licensed professional.

Nameplate values, conductor temperature, power factor, efficiency, weather and actual installation conditions may differ from your entered assumptions.

Confirm units, manufacturer data and the formula's assumptions, then verify sizing with the equipment instructions and applicable local standards.