Manual J Load Calculator
Estimate residential heating loss and sensible cooling gain from building surfaces and air infiltration.
Loading calculator…
What this tool does
Estimate residential heating loss and sensible cooling gain from building surfaces and air infiltration. Simplified estimator, NOT a certified ACCA Manual J calculation. Climate is descriptive; enter local design temperatures explicitly.
How to use the Manual J Load Calculator
- Enter or select floor area in sqft.
- Enter or select ceiling height in ft.
- Enter or select net exterior wall area in sqft.
- Enter or select wall r-value.
- Enter or select ceiling r-value.
- Enter or select window area in sqft.
- Enter or select window u-factor.
- Enter or select door area in sqft.
- Enter or select door r-value.
- Enter or select climate zone (editable design δt below).
- Enter or select heating indoor-outdoor difference (°f).
- Enter or select cooling outdoor-indoor difference (°f).
- Enter or select infiltration ach.
- Enter or select occupants.
- Enter or select appliance heat gain (btu/h).
- Enter or select window solar gain (btu/h per sq ft).
- Read the calculated result; change any measurement to compare alternatives.
Formula
UA=wallArea/wallR+area/roofR+windows×windowU+doors/doorR; infiltrationCFM=area×height×ACH/60; heating=(UA+1.08×CFM)×heatingΔT; cooling=(UA+1.08×CFM)×coolingΔT+windows×solar+people×400+appliances
- area
- Floor area (sqft, before metric conversion)
- height
- Ceiling height (ft, before metric conversion)
- wallArea
- Net exterior wall area (sqft, before metric conversion)
- wallR
- Wall R-value
- roofR
- Ceiling R-value
- windows
- Window area (sqft, before metric conversion)
- windowU
- Window U-factor
- doors
- Door area (sqft, before metric conversion)
- doorR
- Door R-value
- climate
- Climate zone (editable design ΔT below)
- heatingDT
- Heating indoor-outdoor difference (°F)
- coolingDT
- Cooling outdoor-indoor difference (°F)
- ach
- Infiltration ACH
- people
- Occupants
- appliances
- Appliance heat gain (BTU/h)
- solar
- Window solar gain (BTU/h per sq ft)
Simplified estimator, NOT a certified ACCA Manual J calculation. Climate is descriptive; enter local design temperatures explicitly.
Worked example
For manual j load calculator, the following measurements illustrate the exact method: Floor area: 1500; Ceiling height: 8; Net exterior wall area: 1200; Wall R-value: 13; Ceiling R-value: 30; Window area: 200; Window U-factor: 0.35; Door area: 40; Door R-value: 5; Climate zone (editable design ΔT below): mixed; Heating indoor-outdoor difference (°F): 60; Cooling outdoor-indoor difference (°F): 20; Infiltration ACH: 0.5; Occupants: 4; Appliance heat gain (BTU/h): 2000; Window solar gain (BTU/h per sq ft): 50.
Inputs
- Floor area1500 sq ft
- Ceiling height8 ft
- Net exterior wall area1200 sq ft
- Wall R-value13
- Ceiling R-value30
- Window area200 sq ft
- Window U-factor0.35
- Door area40 sq ft
- Door R-value5
- Climate zone (editable design ΔT below)Mixed
- Heating indoor-outdoor difference (°F)60
- Cooling outdoor-indoor difference (°F)20
- Infiltration ACH0.5
- Occupants4
- Appliance heat gain (BTU/h)2000
- Window solar gain (BTU/h per sq ft)50
Result
- Estimated heating loss (BTU/h)19,698.46
- Estimated cooling gain (BTU/h)20,166.15
Results explained
- Estimated heating loss (BTU/h)
- Estimated heating loss (BTU/h) from the formula above. Simplified estimator, NOT a certified ACCA Manual J calculation. Climate is descriptive; enter local design temperatures explicitly.
- Estimated cooling gain (BTU/h)
- Estimated cooling gain (BTU/h) from the formula above. Simplified estimator, NOT a certified ACCA Manual J calculation. Climate is descriptive; enter local design temperatures explicitly.
Frequently asked questions
UA=wallArea/wallR+area/roofR+windows×windowU+doors/doorR; infiltrationCFM=area×height×ACH/60; heating=(UA+1.08×CFM)×heatingΔT; cooling=(UA+1.08×CFM)×coolingΔT+windows×solar+people×400+appliances
Simplified estimator, NOT a certified ACCA Manual J calculation. Climate is descriptive; enter local design temperatures explicitly.
No. Electrical and HVAC results are estimates. Installation must comply with local codes and be checked by a qualified licensed professional.
Nameplate values, conductor temperature, power factor, efficiency, weather and actual installation conditions may differ from your entered assumptions.
Confirm units, manufacturer data and the formula's assumptions, then verify sizing with the equipment instructions and applicable local standards.